Cables

LOW VOLTAGE

  • Flame – Retardant
  • Fire – Resistant
  • Conductor ( CU / TCU / AL )
  • Armored
  • Unarmored
  • Sheathed (XLPE / PE / PVC / LSZH / Lead Sheath / Nylon / Rubber

HIGH VOLTAGE

  • Voltage ( 66kV , 77kV , 110kV , 132kV , 154kV , 230kV , 345kV , 380/400kV , 500kV )
  • Flame – Retardant
  • Fire – Resistant
  • Conductor ( CU / TCU / AL )
  • Armored
  • Unarmored
  • Sheathed (XLPE/ PE / PVC / LSZH / Lead Sheath / Nylon / Rubber )

MEDIUM VOLTAGE

  • Voltage ( 3.6/6kV , 6/10kV , 8.7/15kV , 12/20kV , 18/30kV )
  • Flame – Retardant
  • Fire – Resistant
  • Conductor ( CU / TCU / AL )
  • Armored
  • Unarmored
  • Sheathed (XLPE/ PE / PVC / LSZH / Lead Sheath / Nylon / Rubber )

TELEPHONE CABLE

  • Flame – Retardant
  • Fire – Resistant
  • Conductor ( CU / TCU )
  • Armored
  • Unarmored
  • Screening
  • Sheathed (PE / PVC / LSZH / Rubber compound / Silicon compound )

SOLAR CABLES

  • Electical Performance
    Low Voltage 1.5/1.5 1kv – (1,8)kv
  • Standard
    EN 50618 / TUV 2Pfg 1169-08 / UTE C 32-502
  • Approvals
    CE
    TUV
    EN
    RoHS
  • Thermal Performance
    Maximum service temperature : 120 °C
    Maximum short-circuit temperature : 250  °C(max. 5 s)
    Minimum service temperature: – 40 °C
  • Fire Performance
    Frame non-propagation based on UNE-EN 60332-1 and IEC 60332-1
    LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1
    Low smoke emission based on UNE-EN 61034 and IEC 61034: Light Transmittance > 60%
    Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2
  • Mechanical Performance
    Minimum bending radius: x3 cable diameter
    Impact resistance: AG2 medium severity
  • Chemical Performance
    Chemical & oil resistance: Excellent
    Grease & mineral oil resistance: Excellent
  • UV Resistant
    UV Resistance based on EN 50618 and TUV 2Pfg 1169-08
  • Water Performance
    Water presence: AD8 submerged
  • Estimated Lifetime
    Estimated lifetime 30 years based on UNE-EN 60216-2
  • Other
    Meter by meter marking
  • Installation Conditions
    Open air
    Buried
  • Applications
    Solar PV installations – strings cable

INSTRUMENTATION CABLE

  • Flame – Retardant
  • Fire – Resistant
  • Conductor ( CU / TCU / AL )
  • Armored
  • Unarmored
  • Screening
  • Sheathed (XLPE / PE / PVC / LSZH / Lead Sheath / Nylon / Rubber compound )

DATA TRANSMISSION CABLE

  • Fieldbus cables
  • Profibus cables (RS – 485)
  • Modbus
  • Ethernet cables (Cat-6/7/8)
  • Coaxial cables

THERMOCOUPLE CABLE

  • Thermocouple Extension and Compensating cable
  • Japanese standard (JIS), American standard (ASTM), European standard (IEC)
  • Flame – Retardant
  • Armored
  • Unarmored
  • PVC type, FEP type

FIBRE OPTICS CABLES

  • Steel Tape Armoured Loose Tube
  • Wire Armoured Loose Tube
  • Aerial Self Supporting Slotted Core
  • Unarmour Slotted Core
  • Steel Tape Armoured Slotted Core
  • Write Armoured Slotted Core
  • Drop Cable (Aerial Application)
  • Indoor Cable
  • All Dielectric Self Supporting (ADSS)
  • Flame-Retardant
  • Fire-Resistant
  • Low Smoke Emission
  • Low Corrosive Fume Emission
  • Increased Flexibility
  • Mechanical Resistance
  • Oil-Resistant
  • Mud Oil-Resistant
  • Heavy-Duty
  • Weathering-Resistant

COMPOSITE POWER AND OPTICAL SUBMARINE CABLE

Note: All cables could add in Lead Sheath (LC) or Nylon Jacket (AL-HDPE-PA)